%% Adaptive MPC Control of Nonlinear Chemical Reactor Using Online Model Estimation % This example shows how to use an Adaptive MPC controller to control a % nonlinear continuous stirred tank reactor (CSTR) as it transitions from % low conversion rate to high conversion rate. % % A discrete time ARX model is being identified online by the Recursive % Polynomial Model Estimator block at each control interval. The adaptive % MPC controller uses it to update internal plant model and achieves % nonlinear control successfully. % Copyright 1990-2014 The MathWorks, Inc. %% About the Continuous Stirred Tank Reactor % A Continuously Stirred Tank Reactor (CSTR) is a common chemical system in % the process industry. A schematic of the CSTR system is: % % <<../mpc_cstr.png>> %% % This is a jacketed non-adiabatic tank reactor described extensively in % Seborg's book, "Process Dynamics and Control", published by Wiley, 2004. % The vessel is assumed to be perfectly mixed, and a single first-order % exothermic and irreversible reaction, A --> B, takes place. The inlet % stream of reagent A is fed to the tank at a constant volumetric rate. % The product stream exits continuously at the same volumetric rate and % liquid density is constant. Thus the volume of reacting liquid is % constant. % % The inputs of the CSTR model are: % % $$ \begin{array} {ll} % u_1 = CA_i \; & \textnormal{Concentration of A in inlet feed % stream} [kgmol/m^3] \\ % u_2 = T_i \; & \textnormal{Inlet feed stream temperature} [K] \\ % u_3 = T_c \; & \textnormal{Jacket coolant temperature} [K] \\ % \end{array} $$ % % and the outputs (y(t)), which are also the states of the model (x(t)), are: % % $$ \begin{array} {ll} % y_1 = x_1 = CA \; & \textnormal{Concentration of A in reactor tank} [kgmol/m^3] \\ % y_2 = x_2 = T \; & \textnormal{Reactor temperature} [K] \\ % \end{array} $$ % % The control objective is to maintain the reactor temperature $T$ at its % desired setpoint, which changes over time when reactor transitions from % low conversion rate to high conversion rate. The coolant temperature % $T_c$ is the manipulated variable used by the MPC controller to track the % reference as well as reject the measured disturbance arising from the % inlet feed stream temperature $T_i$. The inlet feed stream % concentration, $CA_i$, is assumed to be constant. The Simulink model % |mpc_cstr_plant| implements the nonlinear CSTR plant. %% About Adaptive Model Predictive Control % It is well known that the CSTR dynamics are strongly nonlinear with % respect to reactor temperature variations and can be open-loop unstable % during the transition from one operating condition to another. A single % MPC controller designed at a particular operating condition cannot give % satisfactory control performance over a wide operating range. %% % To control the nonlinear CSTR plant with linear MPC control technique, % you have a few options: % % * If a linear plant model cannot be obtained at run time, first you need % to obtain several linear plant models offline at different operating % conditions that cover the typical operating range. Next you can choose % one of the two approaches to implement MPC control strategy: % % (1) Design several MPC controllers offline, one for each plant model. At % run time, use Multiple MPC Controller block that switches MPC controllers % from one to another based on a desired scheduling strategy. See % <docid:mpc_examples.example-ex20937898> % for more details. Use this approach when the plant models have different % orders or time delays. % % (2) Design one MPC controller offline at the initial operating point. At % run time, use Adaptive MPC Controller block (updating predictive model at % each control interval) together with Linear Parameter Varying (LPV) % System block (supplying linear plant model with a scheduling strategy). % See <docid:mpc_examples.example-ex18818571> for more details. Use % this approach when all the plant models have the same order and time % delay. % % * If a linear plant model can be obtained at run time, you should use % Adaptive MPC Controller block to achieve nonlinear control. There are % two typical ways to obtain a linear plant model online: % % (1) Use successive linearization. See % <docid:mpc_examples.example-ex07272954> for more details. Use this % approach when a nonlinear plant model is available and can be linearized % at run time. % % (2) Use online estimation to identify a linear model when loop is closed, % as shown in this example. Use this approach when linear plant model % cannot be obtained from either an LPV system or successive linearization. %% Obtain Linear Plant Model at Initial Operating Condition % To linearize the plant, Simulink(R) and Simulink Control Design(TM) are % required. if ~mpcchecktoolboxinstalled('simulink') disp('Simulink(R) is required to run this example.') return end if ~mpcchecktoolboxinstalled('slcontrol') disp('Simulink Control Design(TM) is required to run this example.') return end %% % To implement an adaptive MPC controller, first you need to design a MPC % controller at the initial operating point where CAi is 10 kgmol/m^3, Ti % and Tc are 298.15 K. %% % Create operating point specification. plant_mdl = 'mpc_cstr_plant'; op = operspec(plant_mdl); %% % Feed concentration is known at the initial condition. op.Inputs(1).u = 10; op.Inputs(1).Known = true; %% % Feed temperature is known at the initial condition. op.Inputs(2).u = 298.15; op.Inputs(2).Known = true; %% % Coolant temperature is known at the initial condition. op.Inputs(3).u = 298.15; op.Inputs(3).Known = true; %% % Compute initial condition. [op_point, op_report] = findop(plant_mdl,op); %% % Obtain nominal values of x, y and u. x0 = [op_report.States(1).x;op_report.States(2).x]; y0 = [op_report.Outputs(1).y;op_report.Outputs(2).y]; u0 = [op_report.Inputs(1).u;op_report.Inputs(2).u;op_report.Inputs(3).u]; %% % Obtain linear plant model at the initial condition. sys = linearize(plant_mdl, op_point); %% % Drop the first plant input CAi and second output CA because they are not % used by MPC. sys = sys(1,2:3); %% % Discretize the plant model because Adaptive MPC controller only accepts a % discrete-time plant model. Ts = 0.5; plant = c2d(sys,Ts); %% Design MPC Controller % You design an MPC at the initial operating condition. When running in % the adaptive mode, the plant model is updated at run time. %% % Specify signal types used in MPC. plant.InputGroup.MeasuredDisturbances = 1; plant.InputGroup.ManipulatedVariables = 2; plant.OutputGroup.Measured = 1; plant.InputName = {'Ti','Tc'}; plant.OutputName = {'T'}; %% % Create MPC controller with default prediction and control horizons mpcobj = mpc(plant); %% % Set nominal values in the controller mpcobj.Model.Nominal = struct('X', x0, 'U', u0(2:3), 'Y', y0(1), 'DX', [0 0]); %% % Set scale factors because plant input and output signals have different % orders of magnitude Uscale = [30 50]; Yscale = 50; mpcobj.DV.ScaleFactor = Uscale(1); mpcobj.MV.ScaleFactor = Uscale(2); mpcobj.OV.ScaleFactor = Yscale; %% % Due to the physical constraint of coolant jacket, Tc rate of change is % bounded by 2 degrees per minute. mpcobj.MV.RateMin = -2; mpcobj.MV.RateMax = 2; %% % Reactor concentration is not directly controlled in this example. If % reactor temperature can be successfully controlled, the concentration % will achieve desired performance requirement due to the strongly coupling % between the two variables. %% Implement Adaptive MPC Control of CSTR Plant in Simulink (R) % To run this example with online estimation, System Identification % Toolbox(TM) software is required. if ~mpcchecktoolboxinstalled('ident') disp('System Identification Toolbox(TM) is required to run this example.') return end %% % Open the Simulink model. mdl = 'ampc_cstr_estimation'; open_system(mdl); %% % The model includes three parts: %% % # The "CSTR" block implements the nonlinear plant model. % # The "Adaptive MPC Controller" block runs the designed MPC controller in % the adaptive mode. % # The "Recursive Polynomial Model Estimator" block estimates a two-input % (Ti and Tc) and one-output (T) discrete time ARX model based on the % measured temperatures. The estimated model is then converted into state % space form by the "Model Type Converter" block and fed to the "Adaptive % MPC Controller" block at each control interval. %% % In this example, the initial plant model is used to initialize the online % estimator with parameter covariance matrix set to 1. The online % estimation method is "Kalman Filter" with noise covariance matrix set to % 0.01. The online estimation result is sensitive to these parameters and % you can further adjust them to achieve better estimation result. %% % Both "Recursive Polynomial Model Estimator" and "Model Type Converter" % are provided by System Identification Toolbox. You can use the two % blocks as a template to develop appropriate online model estimation for % your own applications. %% % The initial value of A(q) and B(q) variables are populated with the % numerator and denominator of the initial plant model. [num, den] = tfdata(plant); Aq = den{1}; Bq = num; %% % Note that the new linear plant model must be a discrete time state space % system with the same order and sample time as the original plant model % has. If the plant has time delay, it must also be same as the original % time delay and absorbed into the state space model. %% Validate Adaptive MPC Control Performance % Controller performance is validated against both setpoint tracking and % disturbance rejection. %% % * Tracking: reactor temperature T setpoint transitions from original 311 % K (low conversion rate) to 377 K (high conversion rate) kgmol/m^3. % % * Regulating: feed temperature Ti has slow fluctuation represented by a % sine wave with amplitude of 5 degrees, which is a measured disturbance % fed to MPC controller. %% % Simulate the closed-loop performance. open_system([mdl '/Concentration']) open_system([mdl '/Temperature']) sim(mdl); %% % The tracking and regulating performance is very satisfactory. %% Compare with Non-Adaptive MPC Control % Adaptive MPC provides superior control performance than non-adaptive % MPC. To illustrate this point, the control performance of the same MPC % controller running in the non-adaptive mode is shown below. The % controller is implemented with a MPC Controller block. mdl1 = 'ampc_cstr_no_estimation'; open_system(mdl1); open_system([mdl1 '/Concentration']) open_system([mdl1 '/Temperature']) sim(mdl1); %% % As expected, the tracking and regulating performance is unacceptable. %% bdclose(mdl) bdclose(mdl1)